One zirconia for all indications.
Just glaze it.
Aizir SHT-APM is Aidite’s multilayer zirconia with an integrated three-dimensional colour and translucency gradient. The translucent incisal region (53 per cent) transitions smoothly into a more opaque cervical region (43 per cent), whilst the strength increases from 800 to 1,250 MPa towards the base. This results in natural-looking monolithic restorations that simply need to be glazed.
Thanks to its wide sintering temperature range, Aizir can be processed in the speed programme in under three hours and sintered in a single firing alongside other Aidite zirconia materials (SuperfectZir SHT-PC, SHT-M). Aizir combines several patented technologies from Aidite, which has been developing and manufacturing zirconia for 17 years.
| Type | Multilayer zirconia, pre-coloured (SHT-APM) |
| Flexural strength | 800–1,250 MPa (gradient incisal → cervical) |
| Translucency | 53 % (incisal) 43 % (cervical) |
| Fracture toughness | ≥ 5 MPa·m½ |
| Hardness | ≥ 1,250 HV10 |
| Density (sintered) | ≥ 6.0 g/cm³ |
| Chemical solubility | ≤ 100 µg/cm² |
| Coefficient of thermal expansion (25–500 °C) | 10.5 ± 0.5 × 10⁻⁶ K⁻¹ |
| Sintering | Speed programme 2.7 h (up to 3 units), standard 3.4 h |
| Dimensions | Ø 98.5 mm with shoulder, heights 12–30 mm |
| Colours | VITA classical A1–D4 (16 shades), Bleach OM1, OM2, OM3 |
Manufacturer’s recommendation from Aidite, starting temperature from 20 °C. The curves are guide values – adjust using a temperature measuring ring if necessary, depending on the furnace. For long-span bridges, do not open the furnace until the temperature is below 100 °C.
| Programme | Heating | Final temperature / Holding time | Cooling |
|---|---|---|---|
| Speed, up to 3 units (2.7 h) | 30 °C/min → 1,050 °C, 10 °C/min → 1,300 °C, 5 °C/min | 1,550 °C / 40 min | 60 °C/min up to 900 °C |
| Standard, up to 6 units (3.4 h) | 51.5 °C/min → 1,050 °C, 5 °C/min | 1,550 °C / 60 min | 37.5 °C/min to 800 °C |
| Standard, up to 6 units (3.6 h, e.g. Aidite CSF-200) | 30 °C/min → 1,050 °C, 5 °C/min | 1,550 °C / 60 min | 37.5 °C/min to 800 °C |
| Long span, from 7 units (11.5 h) | 5 °C/min → 900 °C (hold for 30 min), 3 °C/min | 1,530 °C / 120 min | 8 °C/min to 300 °C |
All curves with diagrams, as well as the full processing instructions, can be found under Downloads.
Recommended: anterior and posterior crowns, anterior and posterior bridges – including implant-supported versions.
Suitable: inlays and onlays, veneers, screw-retained bridges, wide-span bridges up to full-arch restorations.
Possible, but not recommended: reduced (cut-back) crowns and bridges, copings and frameworks in the anterior and posterior regions – the colour gradient does not come into its own here.
Design specifications according to Aidite: Minimum wall thickness 0.6 mm (posterior crowns 0.8 mm), connector cross-section at least 9 mm² in the anterior region and 12 mm² in the posterior region, a maximum of two pontics between two abutments, no cantilever pontics.

Scan, design, mill, rapid sinter, glaze: Aizir is designed for a seamless digital workflow and fits into any open milling machine for discs with a diameter of 98.5 mm and a shoulder.
